Updated on 2026-11-19

Reach decides first: 100GBASE-SR4 to 100 m of OM4, 100GBASE-DR to 500 m, CWDM4 or 100G-FR to 2 km, LR4 or 100G-LR to 10 km, ER4 or 100G-ER1-40 to 40 km, ZR4 to 80 km. Budget follows the optics: four-lane CWDM4 and LR4 modules draw under 3.5 W, ER4 under 5 W, ZR4 5.5 W.

Which 100G transceiver matches your reach?

Every variant carries 100 Gb/s of Ethernet payload, and the rows divide by lane count. Seven rows put four 25.78125 GBd NRZ lanes on one module, for 103.125 Gb/s on the fiber (CWDM4 MSA Rev 1.0, Table 2-3). Three rows use one 100G PAM4 lane: 100GBASE-DR, 100G-FR and 100G-LR, with the 100G-ER1 pair extending the same design (IEEE 802.3cd-2018; 100G Lambda MSA 100G-FR/100G-LR Rev 2.0). Two rows are QSFP-DD parts that carry two independent 100G links in one cage (Eoptolink EOLD-162HG-E-02-1 datasheet). The QSFP28 cage follows SFF-8665, and its management interface follows SFF-8636 (SFF-8665; Eoptolink EOLQ-131HG-O-5H-6 datasheet).

Variant Governing spec Lanes, rate and wavelength Reach Max power Price band Port fit
100GBASE-SR4 IEEE 802.3bm-2015 4 × 25G, 850 nm 70 m OM3 / 100 m OM4 < 3.5 W Lowest MPO-12, OM3/OM4
100GBASE-CWDM4 CWDM4 MSA Rev 1.0 4 × 25G, 1271/1291/1311/1331 nm 2 km < 3.5 W Low LC, host FEC
100G 4WDM-10 100G 4WDM MSA 4 × 25G, CWDM grid 10 km < 3.5 W Low-mid LC, host FEC
100G 4WDM-20 100G 4WDM MSA 4 × 25G, LAN-WDM 20 km < 3.5 W Mid LC, 4WDM-20 class
100GBASE-LR4 IEEE 802.3ba-2010 4 × 25G, LAN-WDM 10 km < 3.5 W Mid LC, 6.3 dB
100GBASE-ER4 IEEE 802.3ba-2010 4 × 25G, LAN-WDM 40 km < 5 W Upper LC, 18 dB
100G ZR4 Vendor-defined 4 × 25G, LAN-WDM 80 km engineered 5.5 W Highest LC, host FEC
100GBASE-DR IEEE 802.3cd-2018 1 × 100G PAM4, 1311 nm 500 m < 4.5 W Low-mid LC, KP4 FEC
100G-FR / FR1 100G Lambda MSA; IEEE 802.3cu-2021 1 × 100G PAM4, 1311 nm 2 km < 4.5 W Low-mid LC, KP4 FEC
100G-LR / LR1 100G Lambda MSA; IEEE 802.3cu-2021 1 × 100G PAM4, 1311 nm 10 km < 4.5 W Mid LC, KP4 FEC
2×100G CWDM4 QSFP-DD MSA 8 × 25G, CWDM grid 2 km < 8.0 W Mid Dual CS
2×100G LAN-WDM4 QSFP-DD MSA 8 × 25G, LAN-WDM 10 km < 8.0 W Upper Dual CS

Each reach figure comes with a loss allocation. LR4 gets 6.3 dB of maximum channel insertion loss, ER4 18.0 dB, and CWDM4 an 8.0 dB illustrative budget that includes 5.0 dB of insertion loss (IEEE 802.3ba-2010; CWDM4 MSA Rev 1.0, Tables 2-2 and 2-5). At the IEEE 0.4 dB/km basis plus 2.0 dB for connectors, 10 km uses 6.0 dB and 40 km uses 18.0 dB. A 10 km label describes a plant inside 6.3 dB; extra patch points can push a 9 km route outside it.

SR4 is the only row that needs MPO-12. Every other single-link row terminates in duplex LC, and the 2×100G rows use dual CS. The 100G QSFP28 product family groups the cage and reach classes, and the 100G QSFP28 overview covers the SR4/CWDM4/LR4/DWDM split.

How do the price bands line up?

Four variables move a module between the bands: lane count, laser type (DML, EML, or one PAM4 laser with a gearbox), receiver type (PIN, APD, or a photodiode with an SOA in the 80 km part), and vendor coding plus condition. The 100G Lambda MSA estimates that a single 100G optical lane can cost at least 40% less than four 25G lanes at volume (100G Lambda MSA, About), which is why the DR/FR/LR rows can undercut a four-lane part on price.

The bands follow the bill of materials. SR4 and CWDM4 use DML transmitters and PIN receivers, which keeps them at the low end. ER4 adds EML lasers and an APD array, ZR4 adds an SOA and a VOA, and both move up a band (Eoptolink datasheets). The dual-100G parts land in the middle: one 8 W module replaces two 3.5 W modules. A quotation adds coding and condition, so the table bands are a planning position.

What changes when a 100G module sits in a QSFP-DD cage?

A QSFP-DD cage keeps the QSFP28 footprint and doubles the high-speed lane count to eight, so a QSFP28 module seats and runs at 100G while a later QSFP-DD module uses all eight lanes for 400G (QSFP-DD MSA hardware specification). Four of the eight lanes carry the 100G link; the other four stay idle until a 400G module arrives.

A second reading of “QSFP-DD at 100G” is a module that puts two 100G links in one cage. Eoptolink’s EOLD-162HG-E-02-1 carries 206 Gb/s over eight 25G NRZ lanes, terminates in two CS connectors and reaches 2 km on the CWDM grid at under 8.0 W (EOLD-162HG-E-02-1 datasheet). The EOLD-162HG-E-10-L does the same over 10 km on LAN-WDM. Per 100G port that is 4.0 W, about half a watt above a QSFP28 CWDM4 part, and the patch panel needs two duplex pairs against one for a QSFP28 link.

Sixteen dual-100G modules therefore give 32 links in half the cages of a 32-cage chassis, freeing 16 cages for 400G. Running the same chassis with QSFP28 modules gives 32 × 100G links and leaves the 400G upgrade for a module swap. A 400GBASE-DR4 module is a third path: four 100G lanes on one MPO-12 connector (IEEE 802.3bs-2017), so a 400G port can serve four 100G links through a harness.

For a brownfield 100G plant on duplex LC, the QSFP28 module in a QSFP-DD cage is the cheaper path per port. The 32×100G spine switch is a QSFP28 chassis rated 6.4 Tbps, and the 100G spine-leaf port plan covers the uplink arithmetic. The QSFP-DD catalogue filter lists the 400G switches and modules.

Why do CWDM4 and LR4 use four lanes but different wavelengths?

Both classes put four 25G lanes on one duplex LC pair over G.652, and the wavelength grid separates them. CWDM4 assigns its lanes to 1271, 1291, 1311 and 1331 nm, each held to a ±6.5 nm window on the 20 nm coarse grid that ITU-T G.694.2 defines from 1271 to 1611 nm (CWDM4 MSA Rev 1.0, Table 2-1). LR4 uses 1295.56, 1300.05, 1304.58 and 1309.14 nm, spaced 800 GHz apart on the ITU-T G.694.1 grid near 1310 nm (Eoptolink EOLQ-161HG-10-L datasheet). The two sets share no lane, so a CWDM4 module at one end and an LR4 module at the other have no common wavelength to receive. The same LC connector fits both classes, which is how a wrong pair reaches the rack.

Budget arithmetic explains the reach split. CWDM4 is specified over 2 m to 2 km with an 8.0 dB illustrative power budget that includes 5.0 dB of channel insertion loss (CWDM4 MSA Tables 2-2 and 2-5). LR4 is specified over 2 m to 10 km with 6.3 dB of maximum channel insertion loss (IEEE 802.3ba-2010). At 0.4 dB/km plus a 2.0 dB connection allowance, a 2 km CWDM4 span uses 2.8 dB and a 10 km LR4 span uses 6.0 dB, leaving 0.3 dB inside the LR4 allocation. Ten kilometres is the edge of the LR4 budget, and a patched span with extra connectors can cross it before the distance looks long.

FEC follows the same division. The CWDM4 MSA requires host-side RS(528,514) correction and defines the optical link at a 5 × 10⁻⁵ pre-FEC BER (CWDM4 MSA §1.7). IEEE 802.3ba LR4 is specified without FEC at a 10⁻¹² BER target. A host that cannot enable RS(528,514) can still run LR4 to specification; it cannot run CWDM4 that way.

Two MSA classes extend the four-lane idea past 2 km: 4WDM-10 keeps the CWDM grid to 10 km, and 4WDM-20 moves to LAN-WDM for 20 km (Eoptolink EOLQ-161HG-10-1 and EOLQ-161HG-20-L datasheets). Coherent lists FTLC1155RGPL at 2 km CWDM4 and FTLC1154RDPL at 10 km LR4, both four-lane DFB, duplex LC at 103.1 Gb/s (Coherent product pages). The CWDM4 catalogue record lists the 2 km class with duplex LC.

ER4 margin at 40 km

Forty kilometres is the longest reach in IEEE 802.3ba for 100G, and 18.0 dB is the whole channel budget. The standard sets a 2 m to 40 km range and 18.0 dB of maximum channel insertion loss on the same four LAN-WDM lanes as LR4 (IEEE 802.3ba-2010). At 0.4 dB/km, the fiber accounts for 16.0 dB; the 2.0 dB connection allowance brings the channel to exactly 18.0 dB.

A route that measures 0.35 dB/km uses 14.0 dB of fiber, leaving 2.0 dB for patch panels and repairs. At 30 km the same basis gives 12.0 dB of fiber plus 2.0 dB, or 14.0 dB, which leaves 4.0 dB. The 40 km link therefore has no spare loss on the IEEE basis and about 2 dB on a good plant.

Vendors sell two ER4 behaviours. The lower-power ER4-lite part reaches 30 km without host FEC and 40 km only with FEC enabled. Eoptolink’s EOLQ-161HG-40-LA lists both figures, EOLQ-161HG-40-L7 lists 40 km with FEC, and both use four EML LAN-WDM lasers and an APD receiver array under 5 W (Eoptolink datasheets). A 40 km order that lands an ER4-lite module on a host with FEC disabled delivers 30 km.

The 100G Lambda MSA added a single-lane alternative at the same reach. Its 100G-ER1-40 specification puts one 100G PAM4 lane over 40 km (100G Lambda MSA, December 2020 release). ER1-40 and ER4 both claim 40 km; they use different lane counts and modulation, so the two cannot be paired.

ZR4 versus ER4 plus regeneration

Eighty kilometres needs 34.0 dB at 0.4 dB/km plus 2.0 dB of connections, and the ER4 allocation supplies 18.0 dB of that. Eoptolink’s EOLQ-161HG-80-L7 meets the span with four EML LAN-WDM lasers, a semiconductor optical amplifier, a variable optical attenuator and a photodiode array, draws 5.5 W and requires host FEC (EOLQ-161HG-80-L7 datasheet). No IEEE 802.3 PMD defines 80 km at 100G, so the budget comes from the datasheet.

Two ER4 pairs with a regeneration site at the midpoint carry power, rack space, management and a second set of optics; on a route with no existing hut, that site can cost more than the step from ER4 to ZR4. Where a hut already sits at the midpoint, ER4 plus regeneration can win. A single 80 km span with no intermediate site is the ZR4 case.

The wavelength label needs a check. ZR4 has no IEEE wavelength plan: Eoptolink’s part runs LAN-WDM near 1310 nm, while the QSFP28-ZR4-100G catalogue record lists a 1550 nm part under the same 100GBASE-ZR4 label. Pair modules from one datasheet family, since a 1310-window part and a 1550 nm part do not link.

Spans beyond 80 km leave the direct-detect family and move to a DWDM line system; the 100G DWDM transceiver guide covers channel plans.

The power and cooling bill

Thirty-two 3.5 W modules draw 112 W at the faceplate. The same chassis with 4.5 W DR/FR/LR modules draws 144 W, with 5 W ER4 draws 160 W, and with 5.5 W ZR4 draws 176 W (Eoptolink datasheets; 32×100G spine switch). The 64 W spread between the lowest and highest fill is 57% more optical load for the same port count.

The figures come from Eoptolink brief datasheets and are module maxima; a class ceiling can differ. Models, in table order, are EOLQ-851HG-02-MO, EOLQ-161HG-02-1, EOLQ-161HG-10-1, EOLQ-161HG-20-L, EOLQ-161HG-10-L, EOLQ-161HG-40-L7, EOLQ-161HG-80-L7, EOLQ-131HG-O-5H-6, EOLQ-131HG-O-02-6 and EOLQ-131HG-O-10-6, plus the EOLD pair for the dual-100G rows.

Sixteen 8 W dual-100G modules deliver 32 links at 128 W, or 4.0 W per 100G. That sits between a 3.5 W CWDM4 fill and a 4.5 W single-lambda fill.

A 90%-efficient PSU adds about 11% at the inlet for the same DC load, so the 64 W optical delta becomes about 71 W at the wall. Cage airflow and case temperature carry the rest: the Eoptolink briefs rate commercial case temperature at 0 to 70 °C, and the ZR4 part with its SOA runs closest to that ceiling. A mixed chassis pays the sum of its parts: sixteen CWDM4 and sixteen ZR4 ports draw 144 W (16 × 3.5 + 16 × 5.5).

Which single-lambda 100G module replaces a four-lane one?

100GBASE-DR puts one 53.125 GBd PAM4 lane at 1311 nm over 500 m of G.652 (IEEE 802.3cd-2018). 100G-FR and 100G-LR extend the same single-lane design to 2 km and 10 km under the 100G Lambda MSA, and IEEE 802.3cu-2021 defines the same reaches as 100GBASE-FR1 and 100GBASE-LR1 (100G Lambda MSA 100G-FR/100G-LR Rev 2.0; IEEE 802.3cu-2021).

In a QSFP28 cage these parts still take four 25G NRZ lanes from the host and convert them to one 100G PAM4 optical lane (Eoptolink EOLQ-131HG-O-5H-6 datasheet). The extra DSP work shows up in the power: <4.5 W against <3.5 W for a four-lane CWDM4 or LR4 part, a one-watt penalty per port at 100G.

A DR spare works at either end of any 500 m link, since there is no wavelength grid to match. The cost appears at the host: 100G-LR1 will not link to 100GBASE-LR4 even though both are 10 km 100G optics, because one carries a single PAM4 lane and the other four NRZ lanes.

FEC is mandatory across the branch: KP4 RS(544,514), the code the 100G Lambda MSA names for its 100G and 400G interfaces (100G Lambda MSA, About; IEEE 802.3cd-2018). A host without KP4 FEC cannot use these parts, which puts them on the same host checklist as CWDM4.

Choose single-lambda for new builds where the host supports KP4, the plant is duplex LC, and the reach is 500 m, 2 km or 10 km. Stay with four-lane CWDM4 or LR4 where the installed plant and spare pool are already four-lane, or where 3.5 W per port matters. The 25G and 100G module guide covers the rate and fibre plan.

How do you keep a mixed-vendor 100G estate interoperable?

Same PMD at both ends settles most of it. CWDM4 and LR4 share no lane. LR4 and ER4 share the four LAN-WDM lanes, but each PMD is specified with its own launch power, receiver sensitivity and budget, and neither standard defines a mixed pair. Keep a link on one PMD class and sort the spare pool by class; the label carries the reach class, while the EEPROM carries the vendor code.

FEC settings split across the family: RS(528,514) for CWDM4, KP4 RS(544,514) for DR/FR/LR and the QSFP-DD dual-100G parts, and no FEC in the LR4/ER4 base specifications (CWDM4 MSA §1.7; IEEE 802.3cd-2018; IEEE 802.3ba-2010). A host whose FEC setting is fixed at one regime may not bring up a module from another.

Order codes split three ways: reach class, vendor coding and condition. The same 100GBASE-LR4 optic appears as Infinera TOM-100G-Q-LR4 and Juniper JNP-QSFP-100G-LR4, each with its own part number and platform coding. Count the spare pool in vendor part numbers; the same LR4 class already appears under at least two codes.

SFF-8636 digital diagnostics expose per-lane transmit and receive power, temperature and alarm flags, and the QSFP-DD parts add CMIS (Eoptolink datasheets). Refurbished units should arrive with per-lane readings at temperature and a link test at rated reach; the refurbished equipment inspection checklist covers the test sequence.

Frequently asked questions

Can a 100GBASE-LR4 module pair with a 100GBASE-ER4 module?

The lane wavelengths match, which makes a mixed pair look plausible on paper. Neither standard defines one: LR4 carries a 6.3 dB channel allocation and ER4 18.0 dB, with different transmitter and receiver limits (IEEE 802.3ba-2010). Keep one PMD at both ends, and keep LR4 and ER4 in separate bins in the spare pool.

Does a QSFP-DD port need a QSFP-DD module to run 100G?

No. The cage keeps the QSFP28 footprint and defines backward operation, so a 100G QSFP28 module uses four of the eight lanes and runs at its rated reach (QSFP-DD MSA). A QSFP-DD module is needed for 400G, or for a dual-100G part such as EOLD-162HG-E-02-1, which carries two 100G links at under 8.0 W.

Is 100GBASE-ZR4 defined by IEEE 802.3?

No. IEEE 802.3ba-2010 stops at 100GBASE-ER4, 40 km with 18.0 dB of channel insertion loss. ZR4 is a vendor-defined 80 km class; Eoptolink’s EOLQ-161HG-80-L7 specifies 80 km with host FEC, an SOA and 5.5 W. Wavelength plans vary: parts on LAN-WDM near 1310 nm and parts at 1550 nm both carry the label.

Which forward error correction does each 100G variant need?

CWDM4 needs RS(528,514) per the MSA, and its optical link is defined at 5 × 10⁻⁵ pre-FEC BER (CWDM4 MSA §1.7). DR, FR and LR need KP4 RS(544,514) (IEEE 802.3cd-2018; 100G Lambda MSA). LR4 and ER4 are specified without FEC, while ER4-lite needs FEC for 40 km and reaches 30 km without it (Eoptolink EOLQ-161HG-40-LA datasheet). ZR4 requires host FEC.

Why does a 10 km LR4 link fail on a 9 km span?

The loss budget sets the limit; distance only estimates it. LR4 gets 6.3 dB of channel insertion loss (IEEE 802.3ba-2010). Nine kilometres at 0.4 dB/km uses 3.6 dB, leaving 2.7 dB for connectors, splices and patch panels. A span with several patch points can exceed that. Measure with an OTDR or source-and-meter before moving to ER4; a dirty connector adds loss that the 6.3 dB allocation does not cover.

Can CWDM4 and 4WDM-10 modules be mixed on one link?

Both sit on the 1271–1331 nm CWDM grid, so the lane wavelengths line up. The reach classes differ: CWDM4 is a 2 km MSA class and 4WDM-10 a 10 km class (CWDM4 MSA; Eoptolink EOLQ-161HG-10-1 datasheet). Pair the same class at both ends; the CWDM4 receiver is specified against a 2 km channel, and the 4WDM-10 transmitter against 10 km.

Need a specific part?

Send the part number and quantity — we confirm condition, availability and price before you commit.